Compact Laminate Facade Cladding

Compact laminate (HPL) cladding consists of exterior-grade (EDF) high-pressure laminate panels to EN 438-6, installed on an aluminium substructure as a rear-ventilated facade. The panels are produced by pressing resin-impregnated cellulose fibre layers under high pressure and temperature, and have a decorative surface resistant to UV and weathering.

System and installation

  • Panels are typically 6, 8 or 10 mm thick. Panel thickness and support spacing are determined by structural calculation according to site wind loads.
  • The aluminium substructure of T and L profiles is fixed to the wall with adjustable brackets.
  • Panels are fixed to the substructure with blind rivets. Each panel has one fixed point near its centre, with all other fixings as sliding points, so that dimensional changes from temperature and humidity are accommodated without restraint.
  • A 20–50 mm ventilation cavity is left behind the panels. Continuous airflow driven by the stack effect removes moisture and keeps the insulation dry, while rainwater runs off the panel surface.

Fire classification

Panels are available in standard and fire-retardant (F) grades. The fire-retardant grade achieves B-s2,d0 or B-s1,d0 to EN 13501-1. The grade is selected according to building height and the Turkish Regulation on Fire Protection of Buildings.

Advantages

Wide range of wood, solid colour and metallic finishes; scratch- and impact-resistant surface; easy cleaning and low maintenance.